Create or modify a monitor based on the I-SID entry.
default monitor-by-isid <1–1000> enable
monitor-by-isid <1–1000> egress-mlt <1–512>
monitor-by-isid <1–1000> egress-ports {slot/port[/sub-port][-slot/port[/sub-port]][,...][slot/all][all]}
monitor-by-isid <1–1000> enable
monitor-by-isid <1–1000> map-to-vid <1–4093>
monitor-by-isid <1–1000> monitor-isid-offset <1-1000> {egress-mlt <1–512> egress-ports {slot/port[/sub-port][-slot/port[/sub-port]][,...][slot/all][all]} map-to-vid <1–4093>}
no monitor-by-isid <1–1000> egress-mlt
no monitor-by-isid <1–1000> egress-ports
no monitor-by-isid <1–1000> enable
no monitor-by-isid <1–1000> map-to-vid
a single slot and port (slot/port)
a range of slots and ports (slot/port-slot/port)
a series of slots and ports (slot/port,slot/port,slot/port)
all ports on the same slot (slot/all)
all ports on the switch (all)
Note
If you use the Extreme Integrated Application Hosting (IAH) port 1/s1 as the analyzer port on the monitoring BEB for remote mirroring, you must associate it to VLAN ID 4091.
None
Global Configuration